561,System.IO.IOException: The process cannot access the file 'C:\inetpub\wwwrootResponsive\Content\ExtFiles\CSS561Rpsv.css' because it is being used by another process. at System.IO.__Error.WinIOError(Int32 errorCode, String maybeFullPath) at System.IO.FileStream.Init(String path, FileMode mode, FileAccess access, Int32 rights, Boolean useRights, FileShare share, Int32 bufferSize, FileOptions options, SECURITY_ATTRIBUTES secAttrs, String msgPath, Boolean bFromProxy, Boolean useLongPath, Boolean checkHost) at System.IO.FileStream..ctor(String path, FileMode mode, FileAccess access, FileShare share, Int32 bufferSize, FileOptions options, String msgPath, Boolean bFromProxy, Boolean useLongPath, Boolean checkHost) at System.IO.StreamWriter.CreateFile(String path, Boolean append, Boolean checkHost) at System.IO.StreamWriter..ctor(String path, Boolean append, Encoding encoding, Int32 bufferSize, Boolean checkHost) at System.IO.File.InternalWriteAllText(String path, String contents, Encoding encoding, Boolean checkHost) at MasterPage.getStore() in C:\inetpub\wwwrootResponsive\MasterPage.master.vb:line 233 at MasterPage.Page_Init(Object sender, EventArgs e) in C:\inetpub\wwwrootResponsive\MasterPage.master.vb:line 19 coleman cable cci 50313 23 600v bus drop cable | Gogel Fastener & Industrial
 

2/3 600V BUS DROP Cable

50313

Coleman Cable - CCI

Quick Overview

    Features :-
      • Resistant to oils, lubricants, acids, alkalis, ozone, water and abrasion
      • Individual grounds per conductor
      • Cabled for flexibility
      • Rated for use in wet or dry locations
      • 600V PVC jacketed
Interested in this item or want more information?

Hours:

Phone: 419-243-9144

Email: gogel.fastener@gmail.com

Can't find what you want? Give us a call and we can help you find it.

Details


Construction Parameters :-




Electrical Properties :-

Conductor 2 AWG Bare Copper
Stranding 19/.0591"
Insulation Material PVC
Insulation Thickness 0.062" Nom.
Insulated Conductor Diameter 0.420" Nom.
Ground 12 AWG Bare Copper
Ground Stranding 19/.0185"
Number of Insulated Conductors + Bare Grounds 3 + 3
Lay Length 9.00'' Nom.
Filler Type Polypropylene
Separator Paper Tissue
Jacket Material PVC
Jacket Thickness 0.082'' Nom.
Overall Cable Diameter 1.071" Nom.
Approximate Cable Weight 1019.0 Lbs/1M" Nom
Temperature Rating60°C
Rated Voltage 600 V
DC Resistance per Conductor @ 20°C0.16 Ohms/1M" Nom.
Ampacity Per NEC Table 310.16 and Adjustment Factors per Table 310.15(B)(2)(a)

Additional Information


Manufacturer: Coleman Cable - CCI
For More Information on the 2/3 600V BUS DROP Cable, [Click Here] to Link to Manufacturer Web Site