Details
		 
		  
			Construction Parameters:-
 
|  | 
| Part 1 | 
| Conductor | 18 AWG (1/.040) Solid Copper Clad Steel | 0.040 | 
| Dielectric | Foam Polyethylene | 0.180 | 
| Shielding 1 & 2 | 100% Bonded Aluminum/Polyester/Aluminum Tape plus 40% Aluminum Braid | 0.216 | 
| Shielding 3 & 4 | 100% Aluminum/Polyester/Aluminum Tape plus 60% Aluminum Braid | 0.249 | 
| Part 2 |  | 
| Conductor | 24 AWG (1/.020) Solid Bare Copper | 0.020 | 
| Dielectric | Polyethylene | 0.038 | 
| Assembly | "Two Insulated conductors are twisted into pairs and four pairs are cabled into a Core
core." |   | 
| Final |  | 
| Jacket | "Part 1 and Part 2 are jacketed in a two legged construction with a web between 
each leg" | 0.290 x 0.575 | 
Electrical Properties:-
 
|  | 
|  | VALUE* | 
| Impedance (ohms) |   | 75 | 
| Capacitance pf/ft |   | 17 | 
| Velocity of Propagation (%) |   | 81 | 
| Attenuation (Max db/100 ft) | 10 MHz | 1.85 | 
50 MHz | 1.0 | 100 MHz | 1.3 | 200 MHz | 2.05 | 400 MHz | 3.05 | 700 MHz | 5.95 | 1000 MHz | 7.55 | 1200 MHz | 8.9 | 1450 MHz | 10.1 | 1500 MHz | 10.3 | 2000 MHz | 11.3 | 2500 MHz | 12.2 | 3000 MHz | 13.48 | 
		  
		
		
		  