Quick Overview
Features & Applications:-
- Installs fast & easy to lower labor costs in place of conduit and wire
- Provides superior grounding
- Flexi-Rib™ design is watertight, bends and stays and can be shaped to tight angles
- Lightweight aluminum armor means Corra/Clad weighs less than steel armored cable
- Conductors are soft drawn annealed copper (solid or stranded). Insulation on 18 and 16 AWG is UL Type TFN or TFFN: on 14 AWG and larger, it is UL Type THWN
- Conductors are cabled with fillers and with an overall seamless corrugated continuous aluminum sheath
- Type MC Cable can be furnished with a PVC jacket over the sheath for use in corrosive environments or direct burial.
- Services, feeders and branch circuit
- Power, lighting, control and signal circuits
- Indoors, exposed or concealed
- Direct buried or in concrete encasement (with PVC jacket)
- As aerial cable on a messenger (with PVC jacket)
- In cable trays or as open runs
- Under raised floors, and above suspended ceilings
- Outdoors or in wet locations (with PVC jacket)
- Plenums and any air handling passageway
- Hazardous (classified) environments
- Health care facilities – outer jacket is an approved grounding means and employs a continuous gas/vapor tight aluminum sheath
- Remote-Control Signaling, Power-Limited Circuits, Fire Alarm Systems – Fire/Clad®
Interested in this item or want more information?
Hours:
Phone: 419-243-9144
Email: gogel.fastener@gmail.com
Can't find what you want? Give us a call and we can help you find it.
Details
Construction Parameters :-
Electrical Properties :- |
Conductor | 10 AWG Bare Copper |
Stranding | Solid |
Insulation Material | PVC/Nylon |
Insulation Thickness | 0.026'' Nom. |
Insulated Conductor Diameter | 0.154'' Nom. |
Number of Conductors | 2 |
Lay Length | 4.25'' Nom. |
Filler | Dry Jute |
Separator/Wrap | Clear Mylar |
Armor Material | Corrugated Aluminum |
Armor Thickness | 0.021'' Nom. |
Overall Cable Diameter | 0.466'' Nom. |
Approximate Cable Weight | 127.4 Lbs/1M' Nom. |
Flame Rating | Meets 2 hour through-penetration fire stop requirements. |
|
Temperature Rating | -20°C to 90°C |
Operating Voltage | 600 V RMS Max. |
Capacitance Between Conductors @ 1 KHz | 37 pF/ft Nom. |
Ampacity per NEC Table 310-16 | 40.00 amps per conductor (Assume 2 current carrying conds.) |
DC Resistance per Conductor @ 20°C | 1.00 Ohms/1M' Nom. |